Used DATEX-OHMEDA Datex Cardiocap II Anesthesia Monitor For Sale - DOTmed Listing #1703338: Product details Manufacturer: Datex Ohmeda Item: Datex Cardiocap II Anesthesia Patient Monitor (EKG IBP. DATEX® CARDIOCAP™ II. Features: ECG, SpO2 NIBP, BP Temperature Optional Recorder. It is cost-effective solution for combined hemodynamic and airway gas monitoring for induction rooms, operating rooms, and post anesthesia rooms. Typical Manufacturer’s Picture Specifications Dimensions 330D x 330W x 210H mm/13.4”D x 13”W x 8.3”H. Cardiocap™ II. CardiocapTM II. Patient safety in the operating and recovery room. CardiocapTM II is a combined hemodynamic and airway gas monitor designed specifically for. Automatic hose recognition between Datex-Ohmeda adult/child and infant hoses. Manual, continuous for 5 min, 1, 2, 3, 5, 10. 15, 30, 60 min.

ContentsChapter 1. Overview1.1 About this manual. 1-1Related documentation.

1-11.2 Cardiocap/5 models and features. 1-21.2.1 Options for hemodynami c model (F-MX). 1-21.2.2 Options for hemodynamic model with airway gas measurement (F-MXG). 1-21.2.3 Data collection and management op tions (for F-MX and F-MXG). 1-21.3 Monitor structure. 1-31.3.1 Measurement parameter units. 1-3NESTPR unit.

1-3PVX unit for Patient Spirom etry (N-XV option). 1-4CAiO unit (N-XC, N-XCO, and N-XCAiO options). 1-4Datex-Ohmeda enhanced pulse ox imetry (N-XOSAT option). 1-4Nellcor® compatible pulse oxim etry (N-XNSAT option). 1-4NeuroMuscular Transmission (N-XNMT option). 1-41.3.2 Communication. 1-41.3.3 CPU board.

1-4Distributed processing. 1-51.3.4 Display. 1-51.3.5 I/O board. 1-51.3.6 DC/DC board. 1-51.3.7 AC/DC unit. 1-51.3.8 Recorder (N-XREC option). 1-51.4 Symbol definitions.

1-6Symbols on eq uipment. 1-6Symbols on screens. 1-7Symbols on transport packaging. 1-71.5 Safety precautions.

Datex Cardiocap Ii Manual Free

1-81.5.1 Warnings. 1-8Power connection.

1-8External conn ection. 1-8Electrical shock hazard. 1-9Fuse replacement. 1-9Explosion haz ard. 1-9Patient safety.

1-9Temperature probes. 1-9Cleaning and service. 1-101.5.2 Cautions. 1-10Before us e. Cardiocap/5 Technical Reference ManualAirway gas measurement. 1-10Autoclaving and st erilizing.

1-10Cleaning and service. 1-11Special components and modifications. 1-11Storage and transport. 1-111.5.3 ESD precautionary procedures. 1-11ESD precautionary procedure training.

1-121.5.4 Disposal. 1-121.5.5 Points to note. 1-121.6 Specificat ions. 1-121.6.1 F-MX and F-MXG frames. 1-12Power suppl y.

1-12Environmental co nditions. 1-13LCD display. 1- 131.6.2 NIBP.

1-131.6.3 Temperature. 1-131.6.4 ECG.1-131.6.5 Impedance respiration. 1-141.6.6 Pulse oximetry, standard. 1-141.7 Specifications for opti ons. 1-141.7.1 Classifications. 1-14According to IEC 60601- 1.

1-14Classification according to EU Medical Device Directive. 1-151.7.2 Pulse oximetry, Datex-Ohmeda enhanced (N-XOSAT). 1-151.7.3 Pulse oximetry, Nellcor co mpatible (N-XNSAT). 1-161.7.4 Invasive blood pre ssure (N-XP). 1-161.7.5 Airway gases (N-XC, N- XCO, and N-XCAiO). 1-16Respiration ra te (RR).

1-17Carbon Dioxide (CO2), Oxygen (O2), and Nitrous Oxide (N2O). 1-17Anesthetic agen ts (AA).

1-17Agent identification. 1-18Normal conditions. 1-18Conditions exceed ing normal. 1-181.7.6 Patient Spiromet ry (N-XV). 1-19Conditions exceed ing normal.

1-201.7.7 NeuroMuscular Transmi ssion (N-XNMT). 1-20NMT stimulatio n modes. 1-21Regional bloc k mode. 1-211.7.8 Recorder (N-XREC). OVERVIEW1.1 About this manualThe Technical Reference Manual is for use by service personnel who are qualified to perform serviceand maintenance procedures on the Datex-Ohmeda Cardiocap/5. The information in this manual isbelieved to be accurate and reliable, however, the manufacturer assumes no responsibility for its use.The manual is organized as follows:. Part I (chapter 1 – chapter 4) provides a general overview of the Cardiocap/5, including theinformation needed to install, checkout, and maintain the monitor.

Part I also includesinformation for troubleshooting problems that may occur while using the monitor or that you mayencounter while perfoming procedures in this manual, such as the Functional Check, for example. Part II (chapter 5 – chapter 9) contains detailed functional descriptions of the Cardiocap/5hardware and software, including measurement principles and components for eachmeasurement parameter.

Procedures for replacing parts and making adjustments are alsoincluded. Part II also contains illustrations and detailed descriptions of all service screens usedduring checkout, maintenance, and other service-related activities. A list of parts with illustrationsis located at the end of Part II.Read the entire manual and make sure you understand the procedures described before installing,repairing, or adjusting the monitor. To avoid risks concerning safety or health, strictly observe all safetyprecautions.This manual relates to the monitor versions 6051-0000-164.00 and.01.Related documentationFor information about using the monitor, refer to the following:Cardiocap/5 for Anesthesia User’s GuideCardiocap/5 for Critical Care User’s GuideCardiocap/5 for Anesthesia User’s Reference ManualCardiocap/5 for Critical Care User’s Reference ManualFor PCA drawings, circuit diagrams, and component lists, order the PCA Drawings Service Kit. See theSpare Parts chapter.1-1. Cardiocap/5 Technical Reference Manual1-21.2 Cardiocap/5 models and featuresThe Cardiocap™/5 is a configured monitor that is intended for indoor monitoring of the hemodynamic,respiratory, relaxation, and ventilatory status of the patient. Two models of the monitor are available:hemodynamic (F-MX) and hemodynamic with airway gas measurement (F-MXG).

Both models can beequipped with built-in options. All measurement parameter options (and the Reco rder option, N-XREC) are factory-configuredand cannot be added after purchase. Data collection and management options (N-XNET and N-XDNET) can be added later, if the CPUboard supports Network functionality.1.2.1 Options for hemod ynamic model (F-MX)The F-MX measures NIBP, ECG (3-lead and 5-lead), pulse oximetry (SpO2), temperature (T1), andimpedance respiration. The F-MX can be configured with the following built-in options:N-XP Two invasive pressure channels and second temperature (T2)N-XREC RecorderThe F-MX model can also be configured with one of the following built-in options:N-XNSAT Nellcor® compatible pulse oximetry (SpO2)N-XOSAT Datex-Ohmeda enhanced pulse oximetry (SpO2)1.2.2 Options for hemodynamic model wi th airway gas measurement (F-MXG)The F-MXG measures NIBP, ECG (3-lead and 5-lead), pulse oximetry (SpO2), temperature (T1),impedance respiration, and airway gases.

Cardiocap 5 FeaturesThe GE Datex Ohmeda Cardiocap 5 is a configured monitor that is intended for indoor monitoring of the hemodynamic, respiratory, relaxation, and ventilatory status of the patient. There are two models available for the. One is the hemodynamic (F-MX) and the other is hemodynamic with airway gas measurement (F-MXG). Both models can be equipped with built-in options. 10.4” color LCD display. Recorder that prints trend data and record parameter waveforms.

Hemodynamic and airway gas monitor specifically designed for operating and recovery rooms. Dedicated anesthesia menu logic. Small and Compact. Built-in back-up battery. Convenient mounting system.Cardiocap 5 SpecificationsDimensions.

Height: 11.8” (30 cm). Width: 13” (33 cm). Depth: 8.7” (22 cm). Weight.